Product details
Buffer tank for storing heating and cooling water.
The series of connectors (DIN EN 1092-1) for heat generators and consumers are arranged opposite to each other as charging or discharging connectors. Between these series of connectors there also vertically arranged screw-in options for sensor sleeves, thermometers or similar (3 x Rp 1 1/2, 1 x Rp 1). In addition, there are two DN 180 flange connections. Storage tank of steel S235JR+AR, inside uncoated and outside corrosion protected. The heat losses are measured on an externally certified test bed.
Downloads
Documents
Drawings
-
2D DWG Topvnd.dwg
-
3D DWGvnd.dwg
-
2D DWG frontvnd.dwg
-
2D DWG rightvnd.dwg
-
3D STP
-
PDFpdf
-
2D DWG Top
BIM data
Product photos
-
Article imagejpeg
-
Article image
Accessories
5418900 - fin-tube heat exchanger RWT 2
Auxiliary heat exchanger for installation in Storatherm Aqua AF/1 hot water storage tanks and AF/2 solar cylinders of greater than 750 litres.Installation takes place on site in the available service opening and enables the incorporation of a further heat source, e.g. a solar thermal system, thermal/district heat.Pipe material: Copper ribbed pipe
9116501 - EFHR 16.0
Electric immersion heater from for electric booster heating of Storatherm Heat H.../R and HF.../R heating water buffer cylinders and Storatherm Aqua hot water storage tanks-calorifiers with corresponding installation option via the inspection opening.
Temperature controller up to 85°C target value setting, safety temperature limiter at 110°C. Integrated terminal box. 3 power levels, reversible connections. Including flange and seal. Installation and electrical connection performed on site. Water hardness max. 14°dH, approved for continuous operation.
From 25 kW, the use of a control line is mandatory!
9116502 - EFHR 19.0
Electric immersion heater from for electric booster heating of Storatherm Heat H.../R and HF.../R heating water buffer cylinders and Storatherm Aqua hot water storage tanks-calorifiers with corresponding installation option via the inspection opening.
Temperature controller up to 85°C target value setting, safety temperature limiter at 110°C. Integrated terminal box. 3 power levels, reversible connections. Including flange and seal. Installation and electrical connection performed on site. Water hardness max. 14°dH, approved for continuous operation.
From 25 kW, the use of a control line is mandatory!
9115569 - EFHR 25.0
Electric immersion heater from for electric booster heating of Storatherm Heat H.../R and HF.../R heating water buffer cylinders and Storatherm Aqua hot water storage tanks-calorifiers with corresponding installation option via the inspection opening.
Temperature controller up to 85°C target value setting, safety temperature limiter at 110°C. Integrated terminal box. 3 power levels, reversible connections. Including flange and seal. Installation and electrical connection performed on site. Water hardness max. 14°dH, approved for continuous operation.
From 25 kW, the use of a control line is mandatory!
9118710 - EFHR 2.5
Electric immersion heater from for electric booster heating of Storatherm Heat H.../R and HF.../R heating water buffer cylinders and Storatherm Aqua hot water storage tanks-calorifiers with corresponding installation option via the inspection opening.
Temperature controller up to 85°C target value setting, safety temperature limiter at 110°C. Integrated terminal box. 3 power levels, reversible connections. Including flange and seal. Installation and electrical connection performed on site. Water hardness max. 14°dH, approved for continuous operation.
From 25 kW, the use of a control line is mandatory!
Contact the Reflex Team and further information
Reflex Solutions Pro
- Free to use
- Simple and self-explanatory
- Detailed documentation
:focal(2025x936:2026x937))
Reflex Solutions Pro allows you to design every Reflex and Sinus product into your project quickly and easily. After entering a few system parameters you will receive your custom product solution with all the relevant documentation.
:focal(1743x771:1744x772))
:focal(2030x752:2031x753))
)
:focal(1976x799:1977x800))
:focal(2178x616:2179x617))
:focal(1889x1023:1890x1024))
:focal(1973x660:1974x661))
:focal(1426x934:1427x935))
:focal(1995x840:1996x841))
:focal(924x891:925x892))
:focal(1743x810:1744x811))
:focal(2098x769:2099x770))
:focal(2044x818:2045x819))